How to Measure Material Thickness Through Paint: The UM-2D Ultrasonic Thickness Gauge

Do you need to check the wall thickness of a steel component protected by paint? For some inspections, an ultrasonic thickness gauge with a through-coating mode can measure the underlying material without removing the coating at every test point, provided that the coating condition and inspection procedure allow it.

The UM-2D ultrasonic thickness gauge can measure through paint. Here is what the function is designed for and what to consider when taking a reading.

Wall thickness and coating thickness are different measurements

When inspecting a tank, pipe or steel structure, you may need to determine the remaining thickness of the wall itself. When checking a surface finish, however, the aim is to measure the thickness of the paint or other coating. Each task calls for a suitable instrument and method.

The UM-2D is an ultrasonic gauge for measuring material thickness, including through coatings. A coating thickness gauge is used for a different task: checking the coating itself. Before selecting an instrument, establish which quantity you need to measure and what the underlying material is.

How through-coating measurement works

The ultrasonic gauge uses a signal sent into the component by a probe and the returning echoes. The instrument calculates material thickness using the signal and the selected sound velocity. Couplant is applied between the probe and the surface to help transmit the ultrasound.

Through-coating mode is intended for cases where a paint layer lies between the probe and the material. It does not mean that every painted surface can be measured reliably. Coating adhesion, surface condition and shape, probe selection, instrument settings and material properties all affect the result. Heavily corroded surfaces or flaking paint require particular care when assessing whether the method is suitable.

UM-2D features and specifications

The product page lists a backlit display, memory for 500 readings and an indicator for proper probe contact. The gauge also offers tolerance limits and automatic power-off. Optional accessories include software for processing measurement data.

SpecificationProduct data
Range on steel without coating0.8–250 mm, depending on the probe
Range on steel through coating3–18 mm, depending on the probe
Display resolution0.1 mm / 0.01 mm
Memory500 readings
Power2 × 1.5 V AA batteries

The standard package includes a PT-08 probe, couplant, batteries and a carrying case. Check the documentation and supplied accessories for the version you order. The through-coating range refers to the thickness of the measured material; check suitability for the probe, surface and application in advance.

Preparing for an inspection

  1. Define the measurement. Decide whether you need the wall thickness or the thickness of a surface coating.
  2. Assess access and the surface. Dirt and loose coating can prevent good probe contact. Prepare the surface according to the manual and the inspection requirements.
  3. Set up the instrument. Check the probe, measurement mode and sound velocity for the material. Follow the supplied instructions.
  4. Apply couplant and check contact. Place the probe on the surface and check the contact indicator and reading stability.
  5. Record and verify results. Measure the locations specified in the inspection plan. Repeat suspect readings and record the location, conditions and settings.

For pressure equipment and other critical structures, the inspection scope, assessment and decisions about fitness for service must follow the relevant requirements and an appropriate professional procedure.

Choosing a suitable thickness gauge

Before choosing a gauge, establish the material, expected thickness range, coating type and condition, and access to the test points. Consider whether you need to store readings or transfer them for further processing.

A display resolution of 0.01 mm does not, by itself, guarantee a measurement accuracy of 0.01 mm. Actual results also depend on conditions, correct settings and the complete measurement setup.

For further details, see the UM-2D ultrasonic thickness gauge. Contact us if you would like help selecting a suitable instrument and probe for your application.